Ⓒ 2024 Beye.com. All rights reserved.
This content is intended for health care professionals and providers only. The information contained on Beye.com, including text, graphics, images, and interactive activities, is for informational purposes only, and is not intended to be a substitute for professional medical advice. Beye LLC, via its Editors and Publisher, accepts no responsibility for any injury or damage to persons or property occasioned through the implementation of any ideas or use of any product described herein. Although great care is taken to ensure that all information is accurate, it is recommended that readers seek independent verification of advice on drugs and other product usage, surgical techniques and clinical processes prior to their use. References made in article may indicate usage of medical equipment or drugs at dosages, for periods of time, and in combination not included in the current prescribing information. Inclusion of advertising materials on the website thereof, does not constitute and representation or guarantee by Beye LLC of the quality of such products, or of the claims made.
reset all
At-a-Glance
Description
FDA
CE Mark
Capabilities
Image Capture
Measurements
Modes
Processing
Source
System
Type
Video Capture
CIRRUS photo combines a full mydriatic/non-mydriatic fundus camera with CIRRUS HD-OCT technology in one compact and versatile system. Available in two models, CIRRUS photo 600 and CIRRUS photo 800, it provides multiple insights for comprehensive retina and posterior segment care.
Yes
Yes
Fundus Camera, Retina Thickness, Corneal Thickness Mapping
—
Normative Data Comparison, RNFL Analysis
—
Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free)
—
Not specified
—
Standalone
—
Mydriatic
—
—
—
CIRRUS photo combines a mydriatic/non-mydriatic fundus camera with CIRRUS HD-OCT technology in one compact and versatile system. Available in two models, CIRRUS photo 600 and CIRRUS photo 800, it provides multiple insights for comprehensive retina and posterior segment care.
Yes
Yes
Fundus Camera, Retina Thickness, Corneal Thickness Mapping
—
Normative Data Comparison, RNFL Analysis
—
Fluorescein Angiography, ICG Angiography, Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging
—
Not specified
—
Standalone
—
Mydriatic
—
—
—
The 3D OCT 2000 series of spectral domain OCTs was designed to meet the needs of all eye care professionals from a single doctor practice to a large university hospital.
Yes
Not specified
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping
—
Optic Disc, RNFL Analysis
—
ICG Angiography, Scanning Laser Imaging
—
3D Reconstruction
—
—
—
—
—
The HRA+OCT is a non-contact ophthalmic diagnostic imaging device. It is intended for viewing the posterior segment of the eye, including: two and three dimensional imaging, cross sectional imaging, fundus photography, and fluorescence imaging.
Yes
Yes
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping, RPE Deformation
Not specified
Normative Data Comparison, Optic Disc, RNFL Mapping, RNFL Analysis
Enhanced Depth Imaging (EDI) OCT, Fluorescein Angiography, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging
3D Reconstruction
Powercord
—
Not specified
—
—
The SPECTRALIS OCTPLUS combines Spectral-domain OCT with confocal scanning laser fundus imaging. Like all SPECTRALIS models, the OCTPLUS includes TruTrack active eye tracking and AutoRescan features.
Yes
Yes
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping
Not specified
Normative Data Comparison, RNFL Analysis
Infrared Reflectance, Scanning Laser Imaging
Not specified
Powercord
—
Not specified
—
—
The multi-modality SPECTRALIS HRA offers both fundus and iris FA as well as simultaneous FA and ICGA. SPECTRALIS video angiography can also be combined with red-free, infrared, and BluePeak blue laser autofluorescence.
Yes
Yes
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping
Not specified
Normative Data Comparison, RNFL Analysis
Fluorescein Angiography, ICG Angiography, Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging
Real-Time Video
Powercord
—
Not specified
—
—
The SPECTRALIS FA+OCT provides the diagnostic power of multi-modality imaging by combining Spectral-domain OCT, confocal scanning laser ophthalmoscope (cSLO) fundus imaging, and video angiography.
Yes
Not specified
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping
Not specified
Normative Data Comparison, RNFL Analysis
Fluorescein Angiography, ICG Angiography, Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging
Real-Time Video
Powercord
—
Not specified
—
—
The SPECTRALIS HRA+OCT delivers the ultimate in retinal imaging providing physicians the power of Spectral-domain OCT with TruTrack active eye tracking, AutoRescan features, posterior pole asymmetry analysis combined with five different confocal scanning laser fundus imaging modes and Ultra-Wide Field imaging capability.
Yes
Not specified
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping, RPE Deformation
Not specified
Normative Data Comparison, RNFL Analysis
Fluorescein Angiography, ICG Angiography, Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging
Real-Time Video
Powercord
—
Not specified
—
—
With a touch of the operation screen, the Maestro automatically scans both eyes and produces simultaneously an OCT scan & a true colour fundus image.
Yes
Yes
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping, Corneal Thickness Mapping, Corneal Curvature Mapping
—
Scan Speed (Hz), A-Scan/Second, Scan Depth, Field Angle, Pupil Diameter, Normative Data Comparison, Optic Disc, RNFL Mapping, RNFL Analysis
—
Blue Reflectance (Red-Free), Scanning Laser Imaging
—
3D Reconstruction, Additional Image Processing Features
—
—
—
—
—
The RS-3000 Advanced from Nidek delivers high definition allowing the easy detection of subtle fundus structures and pathology. The model includes repeatable follow up scans of reassuring accuracy using Nidek's tracking and vessel recognition technology, and normative database to aid in diagnosis and comparison of images.
Yes
Not specified
Fundus Camera, Wide-Field Imaging, Retina Thickness, Retinal Mapping, RPE Deformation, Corneal Thickness Mapping (Optional), Corneal Curvature Mapping (Optional)
Not specified
TSNIT Analysis, Normative Data Comparison, Optic Disc, RNFL Mapping, RNFL Analysis, Ganglion Cell Complex
Scanning Laser Imaging
Real-Time Video, 3D Reconstruction
Powercord
—
Not specified
—
—
Avanti Widefield OCT provides information on structures outside the traditional 6x6 mm cube, separates the retina into distinct layers for detailed assessment, offers views of the vitreous and deep choroid, and offers the ability to monitor change over time. Cornea Advance enables visualization and measurement of corneal angles and corneal thickness.
No
Not specified
Retina Thickness, Retinal Mapping
—
Normative Data Comparison, Optic Disc, RNFL Analysis, Ganglion Cell Complex
—
Enhanced Depth Imaging (EDI) OCT
—
3D Reconstruction
—
—
—
—
—
The RS-3000 Advance 2 incorporates a scanning laser ophthalmoscope and is designed for comprehensive imaging and analysis of the retina and glaucoma. Enhancements from the previous model include 85,000 A-scans/s, 12 x 12 mm auto panorama imaging of OCT angiography, and increased image quality.
No
Yes
Fundus Camera, Scanning Laser Imaging
Yes
OCT Angiography+Microperimetry, Normative DB+Microperimetry, Thickness Map DB+Microperimetry, Retinal mode, Choroidal mode
—
Not specified
—
Powercord
—
Not specified
—
—
—
iFusion combines Spectral-Domain OCT and Fundus imaging by adding the OCT capabilities of iVue and high quality imaging from iCam on a single, integrated, versatile platform for your practice. Epi-mapping is now available to provide corneal epithelia and stromal measurements that aid in the diagnosis, documentation, and management of ocular health.
Yes
Not specified
Not specified
—
Not specified
—
Not specified
—
Not specified
—
—
—
—
—
iVue is the compact version of the RTVue OCT, offering the same scanning speed and resolution as the larger system, that includes scanning and reports for retina, retina nerve fiber and cornea assessment by the clinician. Epi-mapping is now available to provide corneal epithelia and stromal measurements that aid in the diagnosis, documentation, and management of ocular health.
Yes
Not specified
Not specified
—
Normative Data Comparison, Optic Disc, RNFL Analysis, Ganglion Cell Complex (Optional)
—
Not specified
—
Optional 3D Reconstruction
—
—
—
—
—
The RTVue Premier was the first FDA-cleared Spectral-Domain OCT launched in the United States, and also the first OCT cleared by the FDA for both corneal and retinal imaging.
Yes
Not specified
Not specified
—
Normative Data Comparison, Optic Disc, RNFL Analysis, Ganglion Cell Complex
—
Not specified
—
Not specified
—
—
—
—
—
Xephilio OCT-A1 Optical Coherence Tomography device, together with the required RX Capture software, computer, and LCD monitor (collectively, the “Xephilio OCT-A1 System”), offers superb image quality. With an Axial digital resolution of 1.6 μm and a high scanning speed of 70,000 A-scans per second, the System enables excellent differentiation of structures and individual layers of the retina and can help with patient comfort.
Yes
Not specified
—
—
—
—
—
—
—
—
—
CIRRUS HD-OCT 500 provides a solution for comprehensive ophthalmic practices and offers essential OCT capabilities with a broad range of clinical applications in an easy-to-learn, easy-to-use instrument for the management of glaucoma and retinal disease, retina assessment for cataract surgery, and anterior segment imaging for corneal disease.
Yes
Yes
Retina Thickness, RPE Deformation, Corneal Thickness Mapping
—
Normative Data Comparison, RNFL Analysis, Ganglion Cell Complex
—
Not specified
—
Not specified
—
—
—
—
—
CIRRUS HD-OCT 5000 is configured with high resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis. This helps to assess glaucomatous loss in the macula that may not be evident in the peripapillary region.
Yes
Yes
Retina Thickness, Corneal Thickness Mapping
—
Normative Data Comparison, RNFL Analysis
—
Not specified
—
Not specified
—
—
—
—
—