Description

FDA

CE Mark

Fluidics Control

Pump Mechanism

Type

  • Fast prime-and-tune cycle, and surgeon settings can be uploaded to any Whitestar Signature System from a memory stick
  • Advanced linear pedal with wireless control for responsiveness and efficiency in each case
  • Monitors IOP and proactively adjusts to maintain pressure
  • Cataract Analysis and Settings Application (CASA) delivers a practice-eye-level view with mobile analytics and case insights

The Whitestar Signature Phacoemulsification System combines the safety of Fusion Fluidics with the optimized cavitation of Whitestar technology. The platform is equipped with Ellips FX Technology and a fusion pump that allows surgeons to switch between peristaltic and venturi intraoperatively. Fusion Fluidics technology anticipates intraocular changes and proactively adjusts the vacuum before occlusion breaks, according to the company.

Yes

Yes

Active

Venturi, Peristaltic

Transversal

remove

close Created with Sketch.
  • Uses a proprietary peristaltic pump designed to minimizes clogging and hold large fragments at the tip
  • Option to use reusable or disposable phaco packs

The Compact Intuitiv System features a user-centric design for value and efficiency. It utilizes the Ellips FX handpiece which provides high-speed cutting and holdability with reduced heat build-up and a proactive IOP management system that responds to occlusion breaks within 20 milliseconds.

Yes

Yes

Active

Venturi, Peristaltic

Transversal

remove

close Created with Sketch.
  • Utilizes the OZil Torsional Handpiece for superior micro-incision procedures
  • Dual sensing technology provides both an exclusive irrigation pressure sensor (IPS) and a vacuum pressure sensor (VPS)
  • Dynamic rise feature allows surgeons to customize vacuum response and aspiration flow rate only when occlusion occurs

The Infiniti Vision System provides enhanced chamber stability and control in a range of energy options including pulse and hyperpulse, smart pulse, and linear burst. It utilizes the OZil Torsional Handpiece which provides side-to-side oscillating ultrasonic movement, the redesigned INTREPID PLUS Fluidics Management System (FMS), and is compatible with the INTREPID AutoSert IOL Injector for single-handed IOL insertion.

Yes

Yes

Passive

Peristaltic

Torsional

remove

close Created with Sketch.
  • Wireless footpedal
  • Active Fluidics utilizes sensors placed along the aspiration and irrigation lines to detect and dynamically compensates for pressure changes by adjusting the compression of a bag of BSS inside the machine

The Centurion Vision System features a peristaltic pump that doubles the available flow rate and eliminates the small pulsations typically associated with peristaltic pumps, according to company literature. Its Active Fluidics technology is designed to optimize chamber stability by providing more consistent IOP over a wide range of aspiration flow rates by detecting flow rate, irrigation pressure, and vacuum and compensating for pressure loss. The Centurion?s OZil handpiece and innovative fluidics enable enhanced emulsification that requires minimal fluid. The INTREPID Balanced Tip is designed to reduce tip movement at the incision, enhancing torsional tip movement at the distal end and providing an alternate straight tip for torsional phaco. The system is also compatible with the INTREPID AutoSert IOL Injector for single-handed IOL insertion and INTREPID Transformer I/A Handpiece which allows surgeons to easily transition from either coaxial or bimanual cortical removal without changing handpieces.

Yes

Yes

Active

Peristaltic

Torsional

remove

close Created with Sketch.
  • Dual light source and surgeon-selected color filters that allow for differentiated viewing designed to enhance the surgeon?s ability to see ocular tissue better under various surgical conditions
  • Wireless dual-linear foot pedal control

The Stellaris PC Vision Enhancement is capable of 1.8 mm MICS phacoemulsification like the Stellaris Vision Enhancement System and high performance 5000 cuts per minute sutureless vitrectomy with the company's existing proprietary 25-gauge system of instruments for retinal surgery, along with standard 23- and 20-gauge instruments.

Yes

Yes

Passive

Venturi

Transversal

remove

close Created with Sketch.
  • Attune Energy Management System and six-crystal handpiece deliver optimized 28.5 kHz frequency for consistent power delivery and increased stroke length.
  • Advanced Vacuum Module StableChamber Fluidics System minimizes surge with a 1.8-mm microincisional cataract surgery tip during high vacuum. (Data on file with Bausch + Lomb.)
  • Wireless dual-linear foot pedal control of aspiration and ultrasound
  • 18" User Interface, Video Inlay and Overlay

The Stellaris Vision Enhancement System features StableChamber fluidics, with which surgeons can customize their fluidics preference, choosing between flow and vacuum control. Part of the platform?s Attune Energy Management System, the six-crystal Attune Handpiece delivers 28.5 kHz frequency for consistent power delivery and increased stroke length.

Yes

Yes

Passive

Venturi

Transversal

remove

close Created with Sketch.
  • Attune Energy Management System and six-crystal handpiece deliver optimized 28.5 kHz frequency for consistent power delivery and increased stroke length.
  • Advanced Vacuum Module StableChamber Fluidics System minimizes surge with a 1.8-mm microincisional cataract surgery tip during high vacuum. (Data on file with Bausch + Lomb.)
  • Wireless dual-linear foot pedal control of aspiration and ultrasound
  • Vitesse hypersonic vitrectomy system

The Stellaris Elite Vision System is designed for use in both anterior and posterior segment surgeries. It provides capabilities for phacoemulsification, coaxial and bimanual irrigation/aspiration, bipolar coagulation, vitrectomy, viscous fluid injection/removal and air/fluid exchange operations. The Stellaris Elite vision enhancement system configured with the laser module is additionally intended for retinal photocoagulation and laser trabeculoplasty. The system is exclusively compatible with the Vitesse hypersonic vitrectomy system that liquefies tissue in a highly-localized zone at the edge of the port and continuously aspirates via an open port design.

Yes

Yes

Active

Venturi

Transversal, Longitudinal

  • 3x faster rise time than traditional Venturi
  • Two Dimensional Cutting tip has a cut speed of up to 8000 cpm and is designed to facilitate cutting tissue on the return of each stroke of the vitrectome, effectively doubling the cut speed

The Eva vitrectomy and phacoemulsification device features an advanced fluid control system called VacuFlow Valve Timing Intelligence (VTi). This system uses VTi to control the transportation of fluids in either vacuum or flow modes, according to company literature. Eva features LEDStar endoillumination for minimal light damage to the retina. The platform also incorporates a 19-inch touchscreen, and its multilingual graphical user interface features voice feedback, an integrated stylus holder, and a remote control.

Not specified

Not specified

Not specified

Venturi, Peristaltic

Not specified

remove

close Created with Sketch.
  • User-friendly and logically aligned control panel
  • CortexMode for greater safety in I/A
  • Highly precise flow control
  • easyPhaco technology for safe and efficient emulsification
  • Easy capsulorhexis with the HF capsulotomy tip
  • Ready for operation within seconds
  • Maximum mobility thanks to light weight and small size
  • Integrated compressor for anterior vitrectomy
  • Robust and precise multifunctional pedal

The CataRhex 3 by Oertli is a consistently compact and portable surgical platform for cataract and glaucoma surgery. The whole load of Oertli’s innovative power is hidden in an impressively small housing. The perfectly precise flow control, the powerful performance and the high user-friendliness of the CataRhex 3, make it the ideal device in eye surgery – in any situation anywhere.

Yes

Yes

Physics and fluidics

Peristaltic and CortexMode

Not specified