Compare Mydriatic Fundus Cameras

arrow Created with Sketch.
arrow Created with Sketch.
24 Products

reset all

At-a-Glance

Description

FDA

CE Mark

Capabilities

Measurements

Modes

Processing

System

Type

  • EOS camera with LCD monitor
  • Camera Modes: Color, Red-Free, Cobalt, Fuorescein Angiography (FA), Fundus Autofluorescence (FAF)
  • Angle of view is 45°
  • Light source is IRED for observation, xenon tube for photography
  • Magnification is 2x (Digital)
  • Minimum pupil size is 4.3mm or more (3.8mm or more when SP function is selected)
  • Working distance is 35mm from the front of objective lens
  • Size is 320 x 531 x 577mm (12.6" x 20.9" x 22.3") and weight is 57 lbs. (26 kg)

The CX-1 Hybrid Digital Mydriatic/Non-Mydriatic (MYD/NM) Retinal Camera is Canon's first hybrid camera and non-mydriatic camera to use Fundus Autofluorescence (FAF) photography.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Angle of view is 45°/27°
  • Light source is Xenon flash lamp
  • Magnification is 2.0x (50°) 3.0x (30°)
  • Minimum pupil size is Ø4.0mm
  • Working distance is 39mm (between objective lens and cornea)
  • Built-in internal fixation target for optic nerve head photography
  • Size is 400 (W) x 520 (D) x 620 (H)mm and weight is 78 lbs. (35.5kg) without video adapter

The VX-10 offers non-mydriatic, mydriatic, and FA modes with a 50° field of view in full mydriatic mode. The optics are mounted on a swing arm to allow photography of the peripheral retina. Small pupil mode enables both color and FA photography in cases of insufficient mydriasis. The VX-10 mydriatic color and fluorescein photography can now be aligned through the LCD observation monitor.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Camera is 24 megapixel CMOS sensor
  • Camera Modes: Color, Fluorescein fundus angiography, (FA)/Red Free, (RF)/Funduc autofleuorescence (FAF)
  • Light source is Xenon flash lamp
  • Minimum pupil size is Ø4.0mm (SP mode: Ø3.5mm)
  • Working distance is 39mm
  • Instant image filing software is included
  • Size is 390 (W) x 540 (D) x 720 (H)mm and weight is 86 lbs. (39 kg)

The VX-20 is Kowa's unique, hybrid combination retinal camera that offers versatile, high quality retinal imaging in one easy-to-use system. Due to its outstanding features, the VX-20 remains the first choice for clinicians.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Camera Modes: Color, Red-Free, Fluorescein
  • Angle of view is 30°, 45° and 50°
  • Minimum pupil size is 3mm
  • Working distance is 40.7mm
  • Fixation target is 4 fixated points
  • Size is 340 (W) x 505 (D) x 535-800 (H)mm and weight is 79.15 lbs. (35.9 kg)

Combines mydriatic and non-mydriatic retinal imaging capabilities into one system. Designed for the comprehensive ophthalmologist, the NW7SF has swing and tilt movement that allows for precise peripheral capture.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Camera Modes: Color, Red-free photography, FA photography, FAF photography
  • Angle of view is 45°
  • Sensor resolution is 12.3 megapixel
  • Minimum pupil size is Ø4.0mm or more, Ø3.3mm or more when the small pupil diaphragm is used
  • Working distance is 40.7mm
  • Size is 274 (W) x 508 (D) x 536-566 (H)mm and weight is 52 lbs. (23.6 kg)

The Topcon TRC-NW8F easy-to-use, auto focus, auto capture mydriatic/non-mydriatic retinal camera is designed to obtain high resolution color and monochrome images of the retina and the anterior segment of the human eye. It is equipped with automatic focusing and capture making it easy to use.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

remove

close Created with Sketch.
  • Single-shot fundus autofluorescence
  • Great detail density
  • Interactive review
  • Multimodal assessments
  • Camera Modes: Autofluorescence, Infrared Reflectance, Blue Reflectance (red-free)
  • Imaging Capabilities: Fundus camera, Retina thickness, Corneal thickness mapping
  • Glauacoma Measurements: Normative Data Comparison, RNFL Analysis
  • Size is 16.1 (W) x 18.9 (D) x 26.8 (H) in. and weight is 32.9 kg (72.7 lbs.)

CIRRUS photo combines a full mydriatic/non-mydriatic fundus camera with CIRRUS HD-OCT technology in one compact and versatile system. Available in two models, CIRRUS photo 600 and CIRRUS photo 800, it provides multiple insights for comprehensive retina and posterior segment care.

Yes

Yes

Fundus Camera, Retina Thickness, Corneal Thickness Mapping

Normative Data Comparison, RNFL Analysis

Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free)

Not specified

Standalone

Mydriatic

remove

close Created with Sketch.
  • Single-shot fundus autofluorescence
  • Great detail density
  • Interactive review
  • Multimodal assessments
  • Camera Modes: Fluorescein Aniography, Autofluorescence, Infrared Reflectance, Blue Reflectance (red-free), Scanning Laser Imaging
  • Imaging Capabilities: Fundus camera, Retina thickness, Corneal thickness mapping
  • Size is 16.1 (W) x 18.9 (D) x 26.8 (H) in. and weight is 32.9 kg (72.7 lbs.)

CIRRUS photo combines a mydriatic/non-mydriatic fundus camera with CIRRUS HD-OCT technology in one compact and versatile system. Available in two models, CIRRUS photo 600 and CIRRUS photo 800, it provides multiple insights for comprehensive retina and posterior segment care.

Yes

Yes

Fundus Camera, Retina Thickness, Corneal Thickness Mapping

Normative Data Comparison, RNFL Analysis

Fluorescein Angiography, ICG Angiography, Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging

Not specified

Standalone

Mydriatic

  • Built-in 12 megapixel CCD camera and a tiltable 8.4-inch color LCD touchscreen
  • Angle of view is 45º (33º in small-pupil photography mode)
  • Light source for observation is Halogen lamp 12V 50W and for capturing is Xenon flash lamp 300Ws
  • Minimum pupil size is ø4.0mm (ø3.3mm in small-pupil photography mode)
  • Working distance is 45.7mm (from objective lens to cornea)
  • Size is 316 (W) x 518 (D) x 579 (H)mm and weight is 64 lbs. (29 kg)

The touchscreen interface on the AFC-330 places all functions at the operator's fingertips with intuitive menus and icons. Exam type, patient selection, database edits, and image review are all possible on the AFC-330's screen.

Yes

Yes

Standalone

Non-Mydriatic

  • Angle of view is 45°
  • Minimum pupil size is 4.0mm or more (Ø3.3mm or more when the small pupil diaphragm is used)
  • Working distance is 40.7mm
  • Integrated digital CCD camera provides 8 megapixel images of superior quality
  • Size is 274 (W) × 508 (D) × 528-558 (H)mm and weight is 22.7 kg

The TRC-NW300 Non-Mydriatic Retinal Camera can be combined with Topcon's IMAGEnet and Synergy Systems for image management and networking. Compatible with today's most popular EMR systems.

Yes

Yes

Standalone

Non-Mydriatic

  • Camera Modes: Color, Red-free
  • Angle of view is 45°
  • Minimum pupil size is 4mm or more
  • Working distance is 40.7mm
  • Features: Auto focus, Auto shoot, Auto small pupil detector
  • Size is 272 (W) x 505 (D) x 530 (H)mm and weight is 24.5 kg

The Topcon TRC-NW8 easy-to-use, auto focus, auto capture non-mydriatic retinal camera is designed to obtain high resolution color and monochrome images of the retina and the anterior segment of the human eye. The TRC-NW8 uses a Nikon digital camera to capture high quality 16.2 MP images.

Yes

Yes

Standalone

Non-Mydriatic

  • Camera Modes: FA/ICG, FAF
  • Sensor resolution is 10.71 megapixels
  • Scientific/medical grade CCD digital camera dedicated to each wavelength

The 11MP Color/B&W Mydriatic Imaging System with FAF/ICG provides complete retinal coverage. It combines IMAGEnet with the Stingray 145 sensor for vascular imaging and the Pike 11MP sensor for film-like color and FA imaging.

Yes

Yes

Standalone

Mydriatic

  • Camera Modes: Color and Black and White
  • Sensor resolution is 10.71 megapixels
  • Sensitive, reliable RGB sensor produces high resolution 11MP Color and FA images

The 11MP Color/B&W Mydriatic Imaging System combines IMAGEnet, the clear standard in mydriatic imaging software, with the Pike 11MP imaging sensor to far surpass the expectations of discerning practitioners looking for film quality.

Yes

Yes

Standalone

Mydriatic

remove

close Created with Sketch.
  • Angle of view is 120 degree when measured from the centre of the eye
  • Sensor resolution is 2040 X 2040 – 24 bit colors
  • Light source is Built-in Compact LED-based warm white illumination
  • Minimum pupil size is 4mm
  • Operating system is Windows 10 pro
  • Size is 210 (L) X 70 (W) X 60 (H)mm and weight is 340 grams (720 gms with cable)

3nethra neo provides a wide field retinal imaging digital camera that captures, stores, and transmits images of an infant's retina to aid in the diagnosis and monitoring of diseases and disorders. The device provides a 120-degree view, enabling doctors to make an informed diagnosis. The 3nethra neo also has a video mode imaging capability that enables the device to convert videos into images.

Yes

Not specified

Point and shoot

Mydriatic

  • Camera Modes: Color fundus, Red-free, FA imaging, ICG, Autoflourescence
  • Angle of view is 50°, 35°, and 20°
  • Light source is Max 300 WS Xenon
  • Magnification is 10X at 50°, 13.3X at 35° and 23.3X at 20°
  • Working distance is 39mm
  • Size is 340 mm(W) x 505 mm(D)x 506-715mm(H) and weight is 35 kg

The TRC-50DX series of mydriatic retinal cameras incorporate the latest digital-ready features to provide complete retinal image capture, including color, red free, fluorescein angiography, fundus auto fluorescein and indocyanine green angiography. It has an easy-to-use touch-screen control panel and 21 levels of flash intensity.

Yes

Yes

Standalone

Mydriatic

remove

close Created with Sketch.
  • Camera is bbuilt-in 12 megapixel CCD
  • Angle of view is 45º (33º in small-pupil photography mode)
  • Light source for observation is halogen lamp 12V 50W and for capturing is Xenon flash lamp 300Ws
  • Minimum pupil size is ø4.0mm (ø3.3mm in small-pupil photography mode)
  • Working distance is 45.7mm
  • Size is 316 (W) x 518 (D) x 579 (H)mm and weight is 64 lbs. (29 kg)

The tiltable 8.4-inch color LCD touchscreen interface on the AFC-330 places all functions at the operator's fingertips with intuitive menus and icons. Exam type, patient selection, database edits, and image review are all possible on the AFC-330's screen.

Yes

Yes

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Angle of view is 40° (spec), 35° (measure)
  • Display screen is LCD 3.5 in
  • Weight is 1 lbs. (445 g)

The Digital Medical Scope VersaCam DS-10 from Nidek offers high quality digital imaging, easy & quick image filing, and simple & easy operation.

Yes

Yes

Point and shoot

Non-Mydriatic

remove

close Created with Sketch.
  • Wide Stimulus & Threshold range measurements for detection of dense scotomas
  • Fully automated measurements
  • High resolution 12 MP camera
  • Precise follow-up examination

The MP-3 Microperimeter measures local retinal sensitivity for functional assessment of the retina. The results can be displayed over a color fundus image, correlating retinal anatomy to retinal function.

remove

close Created with Sketch.
  • Camera Modes: Optomap and Optomap plus (red and green laser), Color composite (green laser view & red laser view), Optomap af (green laser) autofluorescence, optomap fa (blue laser) fluorescein angiography, optomap icg (infra-red) indocyanine angiography
  • Interweaved angiography enables parallel capture of fa and icg images without manually switching between the two
  • Minimum pupil size is 2mm
  • Size is 550 (W) x 550 (D) x 608-632 (H) mm (22 x 22 x 24-25") and weight is 75 lbs. (34 kg)

In addition to the benefits found with all of the UWF devices such as 200 degrees or up to 82% of the retina captured in a single image, in multiple modalities, California incorporates our latest hardware and software technology which enables eyecare professionals to see more, discover more, and treat more ocular pathology.

Yes

Yes

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Camera Modes: Optomap and Optomap plus (red and green laser), Color composite (green laser view and red laser view), Optomap af (green laser), Autofluorescence
  • Minimum pupil size is 2mm
  • Images are available immediately and stored electronically for future comparison or telehealth applications
  • DICOM c ompatible
  •   
  •   Size is 440 mm/18  in (foot print width), 500 mm/20 in (depth), 795 mm/32 in (height) and weight is 28 kg/62 lbs 

In addition to the benefits found with all of the UWF devices such as 200 degrees or up to 82% of the retina captured in a single image, in multiple modalities, Daytona offers multiple wavelength imaging, including options for color, red-free, and autofluorescence with green laser light.

Yes

Yes

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Camera Modes: Color, Red-free
  • Angle of view is 45°
  • Minimum pupil size is >/= 4 mm

The iCam non-mydriatic retinal camera delivers a balanced combination of functions in a compact, portable design.

Yes

Yes

Standalone

Non-Mydriatic

  • SLR camera with PC monitor
  • Camera Modes: Color, Red-free, Fluorescein angiography, Stereo imaging (optional)
  • Angle of view is 50°
  • Light source is halogen lamp for observation, xenon tube for photography
  • Minimum pupil size is 5.2 mm (in SP mode 4.3 mm)
  • Magnification is 2x digital
  • Working distance is 35mm
  • Size is 12.6 inches x 20.9 inches x 22.3 inches (320 mm x 531 mm x 566 mm) and weight is 57 lbs. (26 kg)

The CF-1 Digital Mydriatic Retinal Camera is easy to use and efficient for both doctor and photographer. User-friendly control software helps to ensure efficient workflow, potentially resulting in increased patient throughput.

Yes

Yes

Standalone

Mydriatic

  • Camera Modes: Blue, Green (red-free), Red
  • Angle of view is 50° (11x), 30° (19x), 20° (29x)
  • Magnification is 11x, 19x, 29x
  • Working distance is 42mm
  • Fixation target is external and internal
  • Display is a 19" monitor
  • Size is 430 x 310 x 800mm and weight is 21.5 kg

Matching the VISUPAC system pixel for pixel, the FF 450plus Fundus Camera offers detailed image capture that optimizes the capabilities of the VISUPAC system.

Not specified

Yes

Standalone

Mydriatic

  • Camera Modes: Color
  • Angle of view is Horizontal 30°/ Vertical 25°
  • Light source is Xenon flash lamp/LED
  • Minimum pupil size is Ø5.5mm (SP 1 mode: Ø4.0mm, SP2 mode: Ø3.5mm)
  • Working distance is 5mm
  • Size is 74.5 (W) × 197 (D) × 278.5 (H)mm and weight is 236 lbs.

The GENESIS-D portable, hand held, mydriatic retinal camera is ideal for domiciliary situations or where imaging using a conventional table-mounted camera is not possible. The D model is for color retinal photography with a 2 megapixel digital camera.

Yes

Yes

Point and shoot

Mydriatic

  • Camera Modes: Color and FA
  • Angle of view is Horizontal 30°
  • Light source is Xenon flash lamp/LED
  • Minimum pupil size is Ø5.5mm (SP 1 mode: Ø4.0mm, SP2 mode: Ø3.5mm)
  • Working distance is 5mm
  • Size is 74.5 (W) × 197 (D) × 278.5 (H) mm and weight is 236 lbs.

The GENESIS-D portable, hand held, mydriatic retinal camera is ideal for domiciliary situations or where imaging using a conventional table-mounted camera is not possible. The DF model is for color and FA retinal photography.

Yes

Yes

Point and shoot

Mydriatic