Compare Non-mydriatic Fundus Cameras

arrow Created with Sketch.
arrow Created with Sketch.
18 Products

reset all

At-a-Glance

Description

FDA

CE Mark

Capabilities

Image Capture

Measurements

Modes

Processing

Source

System

Type

Video Capture

remove

close Created with Sketch.
  • Small footprint for office and clinics.
  • Automatic alignment and image capture.
  • Convenient touchscreen tablet interface.
  • Photo montage for extended field of view.
  • Motorized chinrest and quick test time.
  • Cornea capture mode for external images.

An affordable, easy-to-use Non-Mydriatic Ophthalmic Camera for capture, review and export of retinal and external images in busy offices and clinics.

  • EOS camera with LCD monitor
  • Camera Modes: Color, Red-Free, Cobalt, Fuorescein Angiography (FA), Fundus Autofluorescence (FAF)
  • Angle of view is 45°
  • Light source is IRED for observation, xenon tube for photography
  • Magnification is 2x (Digital)
  • Minimum pupil size is 4.3mm or more (3.8mm or more when SP function is selected)
  • Working distance is 35mm from the front of objective lens
  • Size is 320 x 531 x 577mm (12.6" x 20.9" x 22.3") and weight is 57 lbs. (26 kg)

The CX-1 Hybrid Digital Mydriatic/Non-Mydriatic (MYD/NM) Retinal Camera is Canon's first hybrid camera and non-mydriatic camera to use Fundus Autofluorescence (FAF) photography.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Angle of view is 45°/27°
  • Light source is Xenon flash lamp
  • Magnification is 2.0x (50°) 3.0x (30°)
  • Minimum pupil size is Ø4.0mm
  • Working distance is 39mm (between objective lens and cornea)
  • Built-in internal fixation target for optic nerve head photography
  • Size is 400 (W) x 520 (D) x 620 (H)mm and weight is 78 lbs. (35.5kg) without video adapter

The VX-10 offers non-mydriatic, mydriatic, and FA modes with a 50° field of view in full mydriatic mode. The optics are mounted on a swing arm to allow photography of the peripheral retina. Small pupil mode enables both color and FA photography in cases of insufficient mydriasis. The VX-10 mydriatic color and fluorescein photography can now be aligned through the LCD observation monitor.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Camera is 24 megapixel CMOS sensor
  • Camera Modes: Color, Fluorescein fundus angiography, (FA)/Red Free, (RF)/Funduc autofleuorescence (FAF)
  • Light source is Xenon flash lamp
  • Minimum pupil size is Ø4.0mm (SP mode: Ø3.5mm)
  • Working distance is 39mm
  • Instant image filing software is included
  • Size is 390 (W) x 540 (D) x 720 (H)mm and weight is 86 lbs. (39 kg)

The VX-20 is Kowa's unique, hybrid combination retinal camera that offers versatile, high quality retinal imaging in one easy-to-use system. Due to its outstanding features, the VX-20 remains the first choice for clinicians.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Camera Modes: Color, Red-Free, Fluorescein
  • Angle of view is 30°, 45° and 50°
  • Minimum pupil size is 3mm
  • Working distance is 40.7mm
  • Fixation target is 4 fixated points
  • Size is 340 (W) x 505 (D) x 535-800 (H)mm and weight is 79.15 lbs. (35.9 kg)

Combines mydriatic and non-mydriatic retinal imaging capabilities into one system. Designed for the comprehensive ophthalmologist, the NW7SF has swing and tilt movement that allows for precise peripheral capture.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

  • Camera Modes: Color, Red-free photography, FA photography, FAF photography
  • Angle of view is 45°
  • Sensor resolution is 12.3 megapixel
  • Minimum pupil size is Ø4.0mm or more, Ø3.3mm or more when the small pupil diaphragm is used
  • Working distance is 40.7mm
  • Size is 274 (W) x 508 (D) x 536-566 (H)mm and weight is 52 lbs. (23.6 kg)

The Topcon TRC-NW8F easy-to-use, auto focus, auto capture mydriatic/non-mydriatic retinal camera is designed to obtain high resolution color and monochrome images of the retina and the anterior segment of the human eye. It is equipped with automatic focusing and capture making it easy to use.

Yes

Yes

Standalone

Mydriatic/Non-Mydriatic

remove

close Created with Sketch.
  • Single-shot fundus autofluorescence
  • Great detail density
  • Interactive review
  • Multimodal assessments
  • Camera Modes: Autofluorescence, Infrared Reflectance, Blue Reflectance (red-free)
  • Imaging Capabilities: Fundus camera, Retina thickness, Corneal thickness mapping
  • Glauacoma Measurements: Normative Data Comparison, RNFL Analysis
  • Size is 16.1 (W) x 18.9 (D) x 26.8 (H) in. and weight is 32.9 kg (72.7 lbs.)

CIRRUS photo combines a full mydriatic/non-mydriatic fundus camera with CIRRUS HD-OCT technology in one compact and versatile system. Available in two models, CIRRUS photo 600 and CIRRUS photo 800, it provides multiple insights for comprehensive retina and posterior segment care.

Yes

Yes

Fundus Camera, Retina Thickness, Corneal Thickness Mapping

Normative Data Comparison, RNFL Analysis

Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free)

Not specified

Standalone

Mydriatic

remove

close Created with Sketch.
  • Single-shot fundus autofluorescence
  • Great detail density
  • Interactive review
  • Multimodal assessments
  • Camera Modes: Fluorescein Aniography, Autofluorescence, Infrared Reflectance, Blue Reflectance (red-free), Scanning Laser Imaging
  • Imaging Capabilities: Fundus camera, Retina thickness, Corneal thickness mapping
  • Size is 16.1 (W) x 18.9 (D) x 26.8 (H) in. and weight is 32.9 kg (72.7 lbs.)

CIRRUS photo combines a mydriatic/non-mydriatic fundus camera with CIRRUS HD-OCT technology in one compact and versatile system. Available in two models, CIRRUS photo 600 and CIRRUS photo 800, it provides multiple insights for comprehensive retina and posterior segment care.

Yes

Yes

Fundus Camera, Retina Thickness, Corneal Thickness Mapping

Normative Data Comparison, RNFL Analysis

Fluorescein Angiography, ICG Angiography, Autofluorescence, Infrared Reflectance, Blue Reflectance (Red-Free), Scanning Laser Imaging

Not specified

Standalone

Mydriatic

remove

close Created with Sketch.
  • Angle of view is 45 degrees
  • Light source for observation is Infrared Light Emitting Diode
  • Minimum pupil size is 3.0 mm
  • Working distance is 40 mm (from camera lens to Anterior segment)
  • Works on any Windows laptop/PCand integrated telemedicine module enables health records management on the cloud
  • Size is 340 (W) x 498 (D) x 620 (H)mm and weight is 11.3 kgs

The 3nethra classic is a compact, portable, and easy-to-use nonmydriatic digital imaging device. It is designed to acquire, display, store, and transmit images of the posterior and anterior surfaces of the human eye.

Yes

Yes

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • The only device using a patented troxier-free "single fixation" process and "automatic lens density correction" that produces accurate serialized data
  • Electronic Medical Record (EMR) compatible
  • Multifunction device

The MapcatSF is a non-mydriatic, non-invasive device that accurately tracks the macular protective pigment and lens density changes.

Not specified

Not specified

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Auto-alignment, auto-focus, auto-exposure, and auto-capture
  • Imaging modalities include color, IR, and red-free
  • Infrared, live viewing of a wide field (out to 110°) is possible using the programmable internal fixation target.

EIDON combines the advantages of SLO with the fidelity of true color imaging. It provides superb image quality, 60° field in a single exposure, a unique, live, confocal view of the retina, three different imaging modalities and dilation-free operation, in a versatile system. The device is operated via a tablet with a multi-touch, high resolution, color display; it works with a dedicated software application and operates as a standalone unit. A joystick is provided when manual operation of the device is desired.

Yes

Yes

Yes

Color, IR, and red-free

Powercord

Standalone

Not specified

  • EOS camera with LCD monitor
  • Camera Modes: Color, Digital Red-Free, Digital Cobalt
  • Angle of view is 45°
  • Observation light source is Infrared LED
  • Minimum pupil size is 4mm (3.3mm SP mode)
  • Working distance is 35mm
  • High resolution images, making it easier for the diagnosis and detection of a wide range of ocular conditions and diseases
  • Size is 305 x 500 x 473mm (12" x 19.7" x 18.6") and weight is 33 lbs.

The Canon CR-2 Digital Non-Mydriatic Retinal Camera incorporates the latest in Canon retinal imaging technology and enhancements in a compact and light design. Its small design provides the smallest footprint of any Canon retinal camera to date and is portable when needed. 

Yes

Not specified

Standalone

Non-Mydriatic

  • EOS camera with a LCD monitor
  • Camera Modes: Color, Digital Red-Free, Digital Cobalt
  • Angle of view is 45°
  • Observation light source is Infrared LED
  • Minimum pupil size is 4mm (3.3mm SP mode)
  • Working distance is 35mm
  • Size is 12" x 19.7" x 20.2" and weight is 43.9 lbs. (19.9 kg)

The CR-2 AF Digital Non-Mydriatic Retinal Camera features the latest in Canon retinal imaging technology and enhancements in a compact and lightweight design. The CR-2 AF provides auto-functionality with contrast enhancement.

Yes

Not specified

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Dsiplay screen is a LCD monitor
  • Camera Modes: Color, Red-free, Red, Blue, FA, Optional ICGA and FAF
  • Angle of view is 45°, 30°
  • Minimum pupil size is 3.3mm
  • Upgradable to fundus-autofluorescence and indocyanine green angiography
  • FORUM supports bi-directional workflow for supported DICOM enabled devices, reducing charting errors and increasing patient throughput

The VISUCAM NM/FA is an all-integrated design with onboard database system called FORUM.

Yes

Yes

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Camera Modes: Color, Red-free, Red, Blue, Stereo
  • Stereo capture mode for ONH evaluation
  • Angle of view is 45° / 30°
  • Minimum pupil size is 3.3mm
  • Features: Pupil size marker, Positioning aid, Auto-focus, Auto-flash
  • QuickReview lets you switch between capture and review on the spot

The Visucam PRO NM non-mydriatic fundus camera is designed for ease of use and combines optical brilliance and intuitive features in a comprehensive platform for routine fundus imaging procedures, documentation and disease monitoring.

Yes

Yes

Standalone

Non-Mydriatic

  • Camera Modes: Normal, SP, Stereo
  • Angle of view is 45°
  • Minimum pupil size is Ø4.0mm
  • Working distance is 30mm
  • 3D binocular view of the optic cup & disc
  • Simultaneous stereoscopic 3D images
  • Size is 310 (W) X 504 (D) X 548 (H)mm

The nonmyd WX3D is a retinal camera offering both 2D and stereo 3D images. Its uses a specific Nikon digital SLR camera and has a 5.7 inch LCD monitor.

Yes

Yes

Standalone

Non-Mydriatic

remove

close Created with Sketch.
  • Display screen is 5.5 inch LCD monitor
  • Angle of view is 45°/20° optical
  • Minimum pupil size is 3.7 mm
  • Working distance is 30mm
  • Portable VK-2 imaging software included
  • Size is 310 (W) x 504 (D) x 548 (H)mm and weight is 46 lbs. (21kg)

The Kowa nonmyd 7 is a non-mydriatic retinal camera that offers high resolution retinal imaging in three steps – align, focus and shoot.

Yes

Yes

Point and shoot

Non-Mydriatic

remove

close Created with Sketch.
  • Has a 8.3 megapixel CCD camera and a 5.6 in. LCD monitor
  • Camera Modes: Normal, Mosaic
  • Working distance is 30mm
  • Size is 310 (W) x 505 (D) x 462 (H)mm and weight is 48 lbs. (22 kg)
  • Integrated scientific 8mp imaging sensor

Kowa's ophthalmic digital imaging system integrates advanced components and technology that makes this system an indispensable tool for today's practitioner.

Yes

Yes

Standalone

Non-Mydriatic

  • Angle of view is 45° x 40°
  • Minimum pupil size is 4.0mm
  • Working size is 37mm
  • Sensor resolution is 48 pixels/deg
  • Features: patient auto-sensing, auto-alignment, auto-focus, auto flash adjustment, auto-capture
  • Size is 55 x 55 x 33 cm (22’ x 22’ x 13’) and weight is 42 lbs. (19 kg)

The DRS Non-Mydriatic Digital Fundus Camera has a 10.4” touchscreen color display that requires minimal operator training. Its compact, ergonomic design and low power flash help ensure patient comfort.

Yes

Not specified

Standalone

Non-Mydriatic