This content is intended for health care professionals and providers only. The information contained on Beye.com, including text, graphics, images, and interactive activities, is for informational purposes only, and is not intended to be a substitute for professional medical advice. Beye LLC, via its Editors and Publisher, accepts no responsibility for any injury or damage to persons or property occasioned through the implementation of any ideas or use of any product described herein. Although great care is taken to ensure that all information is accurate, it is recommended that readers seek independent verification of advice on drugs and other product usage, surgical techniques and clinical processes prior to their use. References made in article may indicate usage of medical equipment or drugs at dosages, for periods of time, and in combination not included in the current prescribing information. Inclusion of advertising materials on the website thereof, does not constitute and representation or guarantee by Beye LLC of the quality of such products, or of the claims made.
reset all
At-a-Glance
Description
FDA
CE Mark
System
Type
The Marco M3 Autorefractor/Autokeratometer/non-contact tonometer is fully automatic, and uses three axes to track the eye. The M3 also adopts the advanced pupil zone imaging method for refraction measurement.
Yes
Yes
Standalone
—
The Ocular Response Analyzer is capable of measuring corneal biomechanical properties, such as corneal hysteresis, and corneal compensated IOP. It features an all-in-one hardware platform with a 12 inch touch display screen, and is able to plug into a wired keyboard and mouse (optional).
Yes
Yes
Standalone Unit
Applanation
The FT-1000 Non-Contact Tonometer is patient friendly, and notifies patients of measurement timing. The FT-1000 considers patient safety with the touch sensor, and also features doctor-friendly operation, like comfortable operation and constant air pressure.
Yes
Not specified
Standalone Unit
Non-contact
The TRK-2P combines a refractometer, a keratometer, a non-contact tonometer and a pachymeter in one compact instrument. The TRK-2P has a fully auto alignment system with auto measurement function. The compact size and 8,5” rotating color touch screen control panel offers flexibility for the operator and also for instrument location.
No
Yes
Standalone Unit
—
The NT-510 non-contact tonometer features easy automatic alignment and measurement to help the user obtain correct patient measurements. It also includes advanced soft air puff control, an LCD screen and a safety lock to prevent accidental patient contact.
No
Yes
Standalone Unit
Non-contact
The TX-20 Full Auto Tonometer features selectable measurement modes, and a tiltable color LCD monitor to make it easier for the operator to use. The TX-20 also has a fast built-in printer and includes a soft air puff to enhance patient comfort.
Yes
Yes
Standalone
Non-contact
The CT-80 Computerized Tonometer is a non-contact tonometer that features a triple safety function. The CT-80 also features an optional manual control that allows the user to capture measurements.
No
Yes
Standalone Unit
Non-contact
The Topcon CT-800A, non-contact computerized tonometer, enables easy intraocular pressure measurement.
Not specified
Yes
Standalone Unit
Non-contact
The revolutionary Corvis STL records the reaction of the cornea to a defined air pulse with a newly developed high-speed Scheimpflug-camera that takes over 4,300 images per second. IOP and corneal thickness can be measured with great precision on the basis of the Scheimpflug images.
Yes
Yes
Standalone Unit
—
The AT-900 Tonometer is compatible with Haag-Streit 900 series slit lamps, as well as other brands of slit lamps. The AT-900 features the ability to use reusable tonometer prisms or Tonosafe disposable prisms.
Yes
Yes
Slit lamp attachment
Applanation Goldman
The Perkins Mark 2 Tonometer features a tonogrip prism holder and a new ergonomic design. It is tonosafe compatible and includes an integrated rechargable battery.
Yes
Not specified
Handheld
Applanation Goldman
Busy facilities deserve and instrument that will come through in the clutch, which is why Accutome is proud to offer the AccuPen handheld tonometer for patient IOP screening.
Yes
Yes
Handheld
Applanation
The TA01 Tonometer has an ergonomic design that is lightweight and easy to use. The TA01 is hygenic and can help improve patient flow in an ophthalmologist's practice.
Yes
Yes
Handheld
Applanation
The Icare ic100 is based on a rebound measuring principle that requires no drops, air or specialized skills for its use. This device uses patented rebound technology to measure intraocular pressure. Icare's proprietary algorithm coupled with their software allows the device to evaluate deceleration, contact time and other motion parameters of the probe when it touches the cornea. The tonometer also incorporates a new design and user interface.
Yes
Yes
Handheld
Applanation Goldman
Icare HOME tonometer is designed for home use for Glaucoma Patients or suspects, who need regular IOP monitoring by Ophthalmologists recommendation. It is one of the first methods for 24h IOP monitoring outside the clinic.
Yes
Yes
Handheld
Rebound
The Corvis ST records the reaction of the cornea to a defined air pulse with a newly developed Scheimpflug-camera that takes over 4,3000 images per second. IOP and corneal thickness can be measured with precision on the basis of the Scheimpflug images.
No
Yes
Standalone Unit
—
The Diaton tonometer has the ability to measure a patient's IOP through their eyelid. It can measure patients in a reclining position or a sitting position, and sterilization and anesthesia are not required.
Yes
Yes
Handheld
Non-contact
The D-KAT Digital Applanation Tonometer T Type is intended for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. The T type is designed to remove easily and is convenient to use on multiple slit lamps.
Yes
Yes
Slit lamp attachment
Applanation Goldman
The Pulsair intelliPuff is designed to accurately measure intraocular pressure without making contact with the surface of the eye. The intelliPuff also features a built-in printer to provide the user with patient readings.
Yes
Yes
Standalone
Non-contact
The Tono-Pen XL Tonometer features leading edge recognition software to ensure that measurements are only taken at applanation. It is easy to use, and includes an easy-to-read LCD display.
No
Yes
Handheld
Applanation
The Tono-Pen AVIA is an applanation tonometer that features an ergonomic design and takes an average of 10 independent readings to provide reliable tonometry results. It's powered by a POWERCEL Battery pack that lasts over 2,500 measurements, and is lightweight so measurements can be taken anywhere.
Yes
Yes
Handheld
Applanation
The D-KAT Digital Applanation Tonometer R Type is intended for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. The R type is designed to attach to the slit lamp.
Yes
Yes
Slit lamp attachment
Applanation Goldman
The Pulsair Desktop tonometer is an air puff tonometer designed to measure intraocular pressure without making contact with the surface of the eye. The Pulsiar Desktop Tonometer features an adjustable chinrest and 4 non-slip feet to ensure accurate measurements of patients.
Yes
Yes
Standalone Unit
Non-contact
The Reichert 7 Auto Tonometer features a user-friendly touch screen, and is fully automated. The touch screen user interface clearly displays all measurement data, and the Reichert 7 has the ability to connect to EMR systems via a USB port.
No
Yes
Standalone Unit
Non-contact
The Keeler Applanation Tonometer (KAT) type BQ operates according to the Goldmann method, and attaches to the slit lamp. The KAT type BQ is designed specifically to fit the Haag Streit BQ, BP, and BX Slit Lamps and fits directly to the optics support arm.
Yes
Yes
Slit lamp attachment
Applanation Goldman
remove
The Reichert 7CR Auto Tonometer + Corneal Response Technology provides compensated IOP (IOPcc) measurements for the user. The 7CR also features triple measurement mode to provide 3 consecutive IOP measurements in a single button press.
No
Yes
Standalone Unit
Non-contact
The KAT Applanation Tonometer R Type is intended for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. The R type is designed to attach to the slit lamp.
Yes
Yes
Slit lamp attachment
Applanation Goldman
The Model 30 Pneumatonometer is used to measure intraocular pressure non-invasively through applanation tonometry. The Model 30 has the ability to take pulse tonometry, and uses a pneumatic probe to capture accurate measurements.
No
Yes
Standalone Unit
Applanation
The KAT Applanation Tonometer T Type is intended for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. The T type is designed to remove easily and is convenient to use on multiple slit lamps.
Yes
Yes
Slit lamp attachment
Applanation
The PT100 Portable Non-Contact Tonometer is lightweight, ergonomic, and is completely cordless for complete portability. On a single charge, the PT100 can take about 250 measurements.
No
Yes
Handheld
Non-contact
The CT 100 has the ability to mount onto a tower-style slit lamp, and can swing into position when necessary. The CT100 features a classic robust design and includes a slit lamp mount.
Yes
Not specified
Slit lamp attachment
Applanation
The CT 210 mounts on a compact-style slit lamp, and swings into position when necessary. The CT 210 includes a calibration verification rod, and mounts easily onto the slit lamp.
Yes
Yes
Slit lamp attachment
Applanation
The D-KAT Z-type is reliable and easy to use, providing tonometry at it's very best. It operates according to the 'Goldmann method', by measuring intraocular pressure from the force required to flatten (applanate) a constant area (3.06mm) of the cornea. The LED display enables ease of use in darkened environments, whilst the internal electronics allow for the fast accurate measurement of IOP.
Yes
Yes
Slit lamp attachment
Applanation Goldman
Ocular Response Analyzer (ORA) G3 is the only tonometer that measures Corneal Hysteresis (CH), a predictor of glaucoma progression. Corneal Hysteresis is an indication of the biomechanical properties of the cornea differing from thickness or topography, which are geometrical attributes.
Not specified
Not specified
Standalone Unit
Applanation
The HA-2 Applanation tonometer features a unique one-spring mechanism that assures correct readings, regardless of patient posture. The HA-2 also has built-in illumination, which allows the user to take measurements regardless of lighting conditions.
Yes
Yes
Handheld
Applanation
The KT-800 non-contact tonometer features a 5 inch monitor and a thermal line printer. The KT-800 also includes a three-dimensional auto alignment function, and no range switching is necessary when taking a patient's intraocular pressure measurement.
Yes
Yes
Standalone Unit
Non-contact
The NCT-200 features a smart puffing control system that allows the user to adjust air pressure instantly to match the patient's intraocular pressure. The NCT-200 includes a LCD monitor, which has a 40 degree tilt.
No
Yes
Standalone Unit
Non-contact