Compare Glare Testing Devices

arrow Created with Sketch.
arrow Created with Sketch.
5 Products

reset all

At-a-Glance

Description

FDA

CE Mark

remove

close Created with Sketch.
  • Patented LED array 
  • Measure and document glare disability without leaving refracting lane
  • Rechargeable (Comes with charger)
  • Evaluation: Test glare disability at the phoropter with best corrected vision

The EpiGlare offers a standardized, repeatable approach to measuring and documenting glare disability with corrected vision. The Binocular Phoropter Kit includes 2 EpiGlare units.

Yes

Under Investigation

remove

close Created with Sketch.
  • Patented LED array
  • Measure and document glare disability without leaving refracting lane
  • Rechargeable (Comes with a charger)
  • Evaluation: Test glare disability at the phoropter with best corrected vision

The EpiGlare offers a standardized, repeatable approach to measuring and documenting glare disability with corrected vision. The Handheld Desk Kit includes 1 EpiGlare unit and a handle/stand.

Yes

Under Investigation

remove

close Created with Sketch.
  • Patented LED array
  • Measure and document glare disability without leaving refracting lane 
  • Rechargeable Battery (Comes with a charger)
  • Evaluation: Test glare disability at the phoropter with best corrected vision

The EpiGlare offers a standardized, repeatable approach to measuring and documenting glare disability with corrected vision. The Single Phoropter Kit includes 1 EpiGlare unit.

Yes

Under Investigation

remove

close Created with Sketch.
  • Three variable light intensity settings simulate various glare conditions
  • Rechargeable (Comes with charger)
  • LED background illuminator
  • Light Output: High = 400 foot lamberts, Medium = 100 foot-lamberts, Low = 12 foot-lamberts
  • Evaluation: Tinted lenses, Sunglasses, Anti-reflectives, Macular photo stress testing

A recognized industry-standard glare testing device, the Marco BAT is a simple hand-held device that conveniently measures the effects of glare without leaving the exam room.

Yes

Not specified

remove

close Created with Sketch.
  • Computer-controlled, so examination data and results can be saved - standard deviation of individual measuring points
  • Examinations are conducted monocularly
  • The inclination angle of the unit can be adjusted to suit the patient's requirements
  • Evaluation: Amount of straylight in the human eye, Absolute straylight value as a log(s), Graphic display of straylight compared to an age-related normal exam 
  • White LED light source with a maximum brightness of 300 cd/m^2

The C-Quant makes it possible to measure the amount of straylight in a human eye individually and reliably. The effect of increased straylight in the human eye can be compared to looking through a dirty windshield.

Yes

Yes