This content is intended for health care professionals and providers only. The information contained on Beye.com, including text, graphics, images, and interactive activities, is for informational purposes only, and is not intended to be a substitute for professional medical advice. Beye LLC, via its Editors and Publisher, accepts no responsibility for any injury or damage to persons or property occasioned through the implementation of any ideas or use of any product described herein. Although great care is taken to ensure that all information is accurate, it is recommended that readers seek independent verification of advice on drugs and other product usage, surgical techniques and clinical processes prior to their use. References made in article may indicate usage of medical equipment or drugs at dosages, for periods of time, and in combination not included in the current prescribing information. Inclusion of advertising materials on the website thereof, does not constitute and representation or guarantee by Beye LLC of the quality of such products, or of the claims made.
reset all
At-a-Glance
Description
FDA
CE Mark
Data Points
Measurements
Number of Rings
Posterior Cornea
System
Type
The VX130 combines scheimpflug tomography, non-contact tonometry, wavefront aberrometry, and corneal topography in a fully automated diagnostic device.
Yes
Yes
100,000
Tonometry, Elevation and refraction maps, Keratometry, Contact lens fitting, Keratoconus detection, Corneal aberrometry, Pachymetry
24
Yes
—
Scheimpflug, Placido
—
The Topcon CA-800 Corneal Analyzer is an easy-to-use, comprehensive corneal topography solution for evaluation of the anterior corneal surface. In addition to elevation mapping of the corneal surface, the CA-800 includes pupillometry, fluorescein imaging, meibomian gland imaging, contact lens fitting software, white-to-white measurement and Zernike analysis.
Yes
Yes
6,144
White-to-white, Zernike Analysis/Wavefront Aberrometry, Keratoconus Detection
24
Not specified
—
Placido
—
The TMS-4N has comprehensive software that allows the user to customize their own map with their favorite scale, map type, and so on. The Fourier analysis provides refractive information with 3mm and 6mm diameter range.
Not specified
Not specified
7,936
Contact Lens Fitting Software
31
No
—
Placido
—
The Tomey RT-7000 functions as a refractor, keratometer, and topographer. The device features easy and speedy touch-screen alignment, various color maps, contact lens fitting simulation, and corneal eccentricity index for “Ortho-K Lens."
Not specified
Not specified
Not specified
Contact Lens Fitting Software, Keratoconus Detection
Not specified
No
—
Placido
—
The Pentacam AXL is a systematic enhancement of Pentacam HR technology. In addition to anterior segment tomography, the original function of its predecessor, the Pentacam AXL has integrated axial length measurement to make accurate IOL calculations.
Yes
Yes
Not specified
Pachymetry, White-to-white, Contact Lens Fitting Software, Zernike Analysis/Wavefront Aberrometry, Irido-Corneal Angle, Keratoconus Detection, Axial Length
Not applicable
Yes
—
Scheimpflug
—
The Topographic Modeling System TMS-5 is a hybrid anterior segment analyzing system consisting of a Placido ring topographer “TMS” and a 3D Scheimpflug camera. The TMS-5 is indicated for cross sectional imaging of anterior segment components of the human eye such as the anterior and posterior surface of the cornea and the anterior chamber, and also for dimension measurements of these such as curvature, length and area by computed analysis.
Not specified
Yes
7,300
Anterior chamber depth
31
Yes
—
Placido, Scheimpflug
—
The Galilei G4 the simultaneously uses two cameras for speed and different testing methods for accuracy. Placido topography provides anterior corneal curvature, anterior surface irregularity detection, and tear film quality analysis. The dual Scheimpflug tomography provides posterior corneal curvature, pachymetry and elevation, 3D anterior chamber analysis, ray-traced posterior corneal surface data to detect bulging and asymmetry early stages.
Not specified
Not specified
100,000
Zernike Analysis/Wavefront Aberrometry, Keratoconus Detection
20
Yes
—
Placido, Scheimpflug
—
The Orbscan 3 is a third-generation anterior segment analyzer that allows surgeons to examine anterior and posterior astigmatism and optical pachymetry.
Yes
Yes
23,000
Pachymetry, Elevation and Curvature Measurements of Anterior and Posterior Surfaces, White-to-white, Anterior Chamber Depth, Angle Kappa
Not specified
Yes
—
Placido
—
The iTrace Ray Tracing Aberrometer/Topographer is a 5-in-1 system that provides auto-refraction, corneal topography, ray tracing aberrometry, pupillometry and auto-keratometry.
Not specified
Not specified
Not specified
White-to-white, Angle Kappa, Angle Alpha, Pupillometry
Not applicable
Not specified
—
Ray tracing
—
The WaveLight Topolyzer VARIO integrates non-contact topography, keratometry, and pupillometry in a single device.
Yes
Yes
22,000
Pupillometry, Zernike Analysis/Wavefront Aberrometry, Keratoconus Detection
22
Not specified
—
Placido
—
The Aladdin is a combination of an optical biometer and full corneal topographer. The multi-function instrument combines a series of measurements including axial length, corneal topography, pupillometry, corneal diameter and anterior chamber depth to assist in the calculation of IOL power.
Yes
Yes
100,000
Axial Length, Keratometry, Anterior Chamber Depth, Central Corneal Thickness, Lens Thickness, Corneal Topography, Corneal Wave-front Analysis, Pupillometry, White-to-white
24
No
—
Placido
—
The Pentacam is a rotating Scheimpflug camera system for anterior segment analysis. It measures topography and elevation of the anterior and posterior corneal surface and the corneal thickness. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities.
Yes
Yes
25,000
Pachymetry, White-to-White, Contact Lens Fitting Software, Zernike Analysis/Wavefront Aberrometry, Keratoconus Detection
Not applicable
Not specified
—
Scheimpflug
—
The Pentacam HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis that provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities.
Yes
Yes
138,000
Pachymetry, White-to-White, Contact Lens Fitting Software, Zernike Analysis/Wavefront Aberrometry, Keratoconus Detection
Not applicable
Not specified
—
Scheimpflug
—
The Atlas 9000 Corneal Topography System has a range of software packages for in-depth analysis to assist in contact lens fitting, abnormal cornea detection and management, and selection of aspheric IOLs. Patented Cone-of-Focus alignment system and ArcStep algorithm deliver sub-micron elevation accuracy while SmartCapture analyzes 15 digital images per second during alignment and automatically selects the highest quality image for repeatable, reliable results.
Yes
Yes
Not specified
Contact Lens Fitting Software
22
Yes
—
Placido
—
The OPD-Scan III Wavefront Aberrometer is an autorefractor, keratometer, pupillometer (up to 9.5mm), corneal topographer, and integrated wavefront aberrometer. It completes 20 diagnostic metrics in less than 10 seconds per eye (including angle kappa, HOAs, average pupil power, RMS value, and point spread function). Easy alignment and automatic capture of wavefront aberrometry data ensures accurate readings.
Yes
Not specified
11,880
Contact Lens Fitting Software, Keratometry, Pupillometry, Refraction
33
Not specified
Standalone
—
The OPD-Scan III Wavefront Aberrometer is an autorefractor, keratometer, pupillometer (up to 9.5mm), corneal topographer, and integrated wavefront aberrometer. It completes 20 diagnostic metrics in less than 10 seconds per eye (including angle kappa, HOAs, average pupil power, RMS value, and point spread function). Easy alignment and automatic capture of wavefront aberrometry data ensures accurate readings.
Yes
Not specified
11,880
Contact Lens Fitting Software, Keratometry, Pupillometry, Refraction
33
Not specified
Standalone
—
The OCULUS Keratograph 5M is an advanced corneal topographer with a built-in real keratometer and a color camera optimized for external imaging. Unique features include examining the meibomian glands, non-invasive tear film break-up time and the tear meniscus height measurement and evaluating the lipid layer.
Yes
Yes
22,000
Not specified
22
Not specified
—
Placido
—
Cassini uses patented, multicolored LED point-to-point ray tracing to provide a GPS-like analysis of the cornea along with high-resolution images utilized for surgical guidance. The unique measuring principle enables highly accurate and repeatable measurements of the total corneal astigmatism. Integrates with LENSAR Laser System for iris registration to compensate for cyclorotation and improved accuracy.
Yes
Yes
Not specified
Angle Kappa/Lambda, Pupillometry, White-to-white, Zernike Analysis/Wavefront Aberrometry, Keratoconus Detection
Not applicable
Yes
—
LED Triangulation
—